WNS Series 2 Pass Boiler

Product thermal capacity: 1-20 t/h
Working pressure: 0.7-2 MPa
Available fuel: Natural gas, coke oven gas, biogas, diesel, heavy oil, light oil, crude oil, etc.
Available industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Introduction of WNS Series 2 Pass Boiler

The WNS series 2 pass boiler is a horizontal, fully wet-back gas/oil boiler equipped with advanced burners from both domestic and international sources. The WNS series 2 pass boiler features automation in its operation; fuel is atomized by the burner and ignited to create a flame that fills the entire corrugated furnace. This flame transfers radiant heat through the walls of the corrugated furnace, representing the first pass. The high-temperature flue gas produced during combustion collects in the combustion chamber and then flows into the second pass, which consists of the threaded smoke tube bundle area. Here, enhanced convective heat exchange occurs, gradually reducing the flue gas temperature before it reaches the front smoke box. The gas then passes through the economizer and condenser, ultimately being discharged into the atmosphere.

The WNS series 2 pass boiler utilizes high-quality heat-resistant materials and advanced manufacturing techniques to ensure long service life and high stability. Additionally, it is equipped with an intelligent control system that can monitor operating conditions in real-time and automatically adjust the combustion and heating processes, ensuring the equipment operates at optimal performance at all times.

Features of WNS Series 2 Pass Boiler

Efficient Heat Transfer: The WNS series 2 pass boiler adopts a two-pass design, combining a corrugated furnace and threaded smoke tubes to maximize heat transfer efficiency. This design allows the boiler to achieve a thermal efficiency of over 98%, significantly reducing energy consumption.

Environmentally Friendly and Low Emissions: The WNS series 2 pass boiler is equipped with an advanced low-NOx burner, which effectively reduces the emissions of harmful substances such as nitrogen oxides (NOx). It meets stringent international environmental standards, helping companies lower carbon emissions and minimize environmental impact.

Smart Operation: The WNS series 2 pass boiler is equipped with an intelligent control system that monitors operating conditions in real-time and automatically adjusts combustion and heating processes. This not only enhances operational convenience but also ensures that the equipment operates at optimal performance, reducing the risk of malfunctions.

Durable and Stable: The WNS series 2 pass boiler uses high-quality heat-resistant materials and advanced manufacturing techniques to ensure long service life and high stability. This reduces the frequency of maintenance and lowers long-term operational costs.

Specification of WNS Series 2 Pass Boiler

Model Rated steam capacity (t/h) Rated working pressure (MPa) Rated steam temperature (℃) Feed water temperature (℃) Maximum transport weight (t) Maximum transport dimension (m)
WNS1-0.7-Q(Y) 1 0.7 170 20 4.5 3.25×1.80×2.00
WNS1-1.0-Q(Y) 1 1.0 184 20 4.5 3.25×1.80×2.00
WNS1.5-1.0-Q(Y) 1.5 1.0 184 20 7.0 3.65×2.05×2.45
WNS1.5-1.25-Q(Y) 1.5 1.25 194 20 7.0 3.65×2.05×2.45
WNS2-1.0-Q(Y) 2 1.0 184 20 9.0 4.60×2.20×2.60
WNS2-1.25-Q(Y) 2 1.25 194 20 9.0 4.60×2.20×2.60
WNS3-1.0-Q(Y) 3 1.0 184 20 11.5 5.35×2.40×2.80
WNS3-1.25-Q(Y) 3 1.25 194 20 11.5 5.35×2.40×2.80
WNS4-1.25-Q(Y) 4 1.25 194 20 15.0 5.00×2.60×2.95
WNS4-1.6-Q(Y) 4 1.6 204 20 15.0 5.00×2.60×2.95
WNS5-1.25-Q(Y) 5 1.25 194 20 18.0 5.55×2.658×3.20
WNS5-1.6-Q(Y) 5 1.6 204 20 18.0 5.55×2.658×3.20
WNS6-1.25-Q(Y) 6 1.25 194 20 19.5 5.93×2.80×3.20
WNS6-1.6-Q(Y) 6 1.6 204 20 19.5 5.93×2.80×3.20
WNS8-1.25-Q(Y) 8 1.25 194 20 25.0 7.00×2.80×3.25
WNS8-1.6-Q(Y) 8 1.6 204 20 25.0 7.00×2.80×3.25
WNS10-1.25-Q(Y) 10 1.25 194 104 27.5 7.65×2.80×3.25
WNS10-1.6-Q(Y) 10 1.6 204 104 27.5 7.65×2.80×3.25
WNS15-1.25-Q(Y) 15 1.25 194 104 40.0 7.95×3.50×3.75
WNS15-1.6-Q(Y) 15 1.6 204 104 40.0 7.95×3.50×3.75
WNS20-1.25-Q(Y) 20 1.25 194 104 52.0 8.55×3.90×4.15
WNS20-1.6-Q(Y) 20 1.6 204 104 52.0 8.55×3.90×4.15